Name:Danfoss High/Low Pressure Switch with Adjustable Reset (KP series)KP5 060-1173 HP/Manual
Model No.:KP5 060-1173
Place of Origin:China
Brand:Danfoss
Colour:White
Usage:Control Switch
Explosion-proof Type:Flameproof
Structure:Amplifier Built-in Type
HS Code:8414301990
Detection Method:Correlation Type
Contact:Normally Open
Contact Type:Type b Contact
Application:Home, Commercial
weight:0.32kg

Product Description

Danfoss High/Low Pressure Switch with Adjustable Reset (KP series)KP5 060-1173  HP/Manual

 

Product Description

KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.

Product Features

1,KP Dual Pressure Controls are available in versions for regulation of high pressure on both left and right side or regulation of low pressure on left and high pressure on right side (versions with LP signal or LP+HP signals). Enclosure rating IP30 or IP44.

2,Ultra-short bounce time thanks to snap-action function (reduces wear to a minimum and increases reliability)

3,Manual trip function (electrical contact function can be tested without the use of tools)

4,Vibration and shock resistant

5,Compact design

6,Fully welded bellows element

7,High reliability both electrically and mechanically


Pressure controls are pressure-activated switches, with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system.

The set point at which a control closes a contact and makes a circuit is called the cut-in point.

The point at which the control opens the switch and breaks the circuit is called the cut-out point.

The difference between the cut-in and cut-out point is known as the differential.


1. KP pressure controls are for use in refrigeration and air conditioning systems to give protection

Against excessively low suction pressure or excessively high discharge pressure.
2. KP pressure controls are also used for starting and stopping refrigeration compressors and fans
On air-cooled condensers.
3. KP pressure controls are fitted with a single-pole double-throw (SPDT) switch. The position of the
Switch is determined by the pressure control setting and the pressure at the connector.

Item No. pressure Low pressure High pressure Reset Contact System Product code
Adjust range
(bar)
Differential pressure
(bar)
Adjust range
(bar)
Differential pressure
(bar)
Adjust range
(bar)
Differential pressure
(bar)
1/4in
6mm
flare
1/4in
ODF
solder
6mm
ODF
solder
KP1 Low -0.2-7.5 0.7-4.0

Auto
SPDT 060-1101 060-1112 060-1110
KP1 Low -0.9-7.0 Fixed 0.7

Manual
060-1103 060-1111 060-1109
KP2 Low -0.2-5.0 0.4-1.5

Auto
060-1120
060-1123
KP5 High

8-32 1.8-6.0
Auto 060-1171 060-1179 060-1177
KP5 high

8-32 Fixed 3 Auto Manual 060-1173 060-1180 060-1178
KP15 Dual -0.2-7.5 0.7-4.0 8-32 Fixed 4 Auto Auto SPDT+
Low
signal
060-1241 060-1254
KP15 Dual -0.2-7.5 0.7-4.0 8-32 Fixed 4
Manual 060-1243

KP15 Dual -0.9-7.0 Fixed 0.7 8-32 Fixed 4 Manual Manual 060-1245

KP15 Dual -0.2-7.5 0.7-4.0 8-32 Fixed 4 Auto Auto SPDT+
Low/high
signal
060-1265 060-1299
KP15 Dual -0.2-7.5 0.7-4.0 8-32 Fixed 4 Auto Manual 060-1264 060-1284
KP35 Low -0.2-7.5 0.7-4.0

Auto
SPDT 060-1133 G1/4
KP36 Low 2-14 0.7-4.0

Auto
060-1108 G1/4
KP38 High

8-32 1.8-6.0
Auto 060-5081 G1/4
Hits: 【Print】