Location:Index--->Product Center >> Copeland Compressors >> ZB58KQE-TFD-551 Copeland Air Conditioner Scroll Compressor 8HP
|
Product Description
ZB58KQE-TFD-551 Copeland Air Conditioner Scroll Compressor 8HP
Model | QTY/Pallet | Mark |
ZB58KQ-TFD-550 | 12pcs | 380V welding Copeland Suzhou factory |
ZB58KQ-TFD-551 | 12pcs | 380V Threaded Copeland Suzhou factory |
ZB58KQE-TFD-550 | 12pcs | 380V welding Copeland Suzhou factory |
ZB58KQE-TFD-551 | 12pcs | 380V Threaded Copeland Suzhou factory |
Model | Nominal power HP |
Exhaust volume | Starting current A |
Pipe outer diameter | Weight Kg |
Overall dimension mm |
Filling volume L |
Discharge/Suction | |||||||
Inch | |||||||
ZB58KQ/E-TFD-551/0 | 8 | 22.1 (m3/h) | 95 | 7/8 11/8 | 57 | 264*284*477 | 2.51 |
Double flexible design
Ensures a tight seal between the scroll disks. Allows the scroll disks to separate radially and axially, allowing debris or liquids to pass through the scroll disks without damaging the compressor.
- Higher life and reliability
- Better liquid tolerance
- Better tolerance of contaminants
High energy efficiency Scroll disk break-in rather than wear out
- Better performance with increased running time
- High volumetric efficiency
Lower noise and vibration levels Smooth sound spectrum and soft sound quality
- Compression chamber is symmetrically distributed
- Very low unbalanced stresses
- High precision manufacturing process
- No need for vibration absorbers
Unloaded start-up technology
Compressor components are separated from each other after shutdown and are fully pressure balanced within the compressor, without the need for an additional start-up device.
High strength DU bearings
- Upper main and drive bearings
- Space-age materials (1) porous, permeable bronze (2) PTFE coating
- Extended run time without full lubrication
- Very low coefficient of friction
Copeland Refrigeration Scroll Compression Technology provides an outstanding solution for refrigeration applications. Scroll compressors are ideal for high reliability, energy efficiency, and compact system designs.The ZB series is available in a range of products from 2 to 30 HP, and for refrigerants such as R22, R404A, R134a, etc. The ZB series is available in a range of products from 2 to 30 HP, and for refrigerants such as R22, R404A, and R134a.
TECHNICAL DATA | |||||||
Model | ZB15KQ | ZB19KQ | ZB21KQ | ZB26KQ | ZB29KQ | ZB38KQ | ZB45KQ |
ZB15KQE | ZB19KQE | ZB21KQE | ZB26KQE | ZB29KQE | ZB38KQE | ZB45KQE | |
Motor Type | TFD | TFD | TFD | TFD | TFD | TFD | TFD |
PFJ | PFJ | PFJ | PFJ | PFJ | |||
Power(HP) | 2 | 2.5 | 3 | 3.5 | 4 | 5 | 6 |
Displacement(m³/h) | 5.92 | 6.8 | 8.6 | 9.9 | 11.4 | 14.5 | 17.2 |
Starting Current(LRA) | |||||||
TFD | 24.5-26 | 30-32 | 36-40 | 41-46 | 50 | 58.6-65.5 | 67-74 |
PFJ | 53-58 | 56-61 | 75-82 | 89-97 | 113 | ||
Rated Load Current(RLA) | |||||||
TFD | 4.3 | 4.3 | 5.7 | 7.1 | 7.9 | 8.9 | 11.5 |
PFJ | 11.4 | 12.9 | 16.4 | 18.9 | 19.3 | ||
Max. Operating Current(MCC) | |||||||
TFD | 6 | 6 | 8 | 10 | 11 | 12.5 | 16.1 |
PFJ | 16 | 18 | 23 | 24 | 27 | ||
Motor Run | 40μF/370V | 40μF/370V | 55μF/370V | 60μF/370V | 60μF/370V | ||
Crankcase Heater Power(W) | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
Size of Connecting Pipe(INCH) | |||||||
Outer Diameter of Wxhaust Pipe | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
Outer Diameter of Suction Pipe | 3/4 | 3/4 | 3/4 | 3/4 | 7/8 | 7/8 | 7/8 |
Dimensions(MM) | |||||||
Length | 242 | 242 | 243 | 243 | 242 | 242 | 242 |
Width | 242 | 242 | 244 | 244 | 242 | 242 | 242 |
Height | 383 | 383 | 412 | 425 | 430 | 457 | 457 |
Foot Bottom Installation Dimensions(Aperture) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) |
Fuel Injection(L) | 1.18 | 1.45 | 1.45 | 1.45 | 1.89 | 1.89 | 1.89 |
Weight(KG) | |||||||
Net.W | 23 | 25 | 27 | 28 | 37 | 38 | 40 |
Gross.W | 26 | 29 | 30 | 31 | 40 | 41 | 44 |
TECHNICAL DATA | |||||||
Model | ZB48KQ | ZB58KQ | ZB66KQ | ZB76KQ | ZB88KQ | ZB95KQ | ZB114KQ |
ZB48KQE | ZB58KQE | ZB66KQE | ZB76KQE | ||||
Motor Type | TFD | TFD | TFD | TFD | TFD | TFD | TFD |
Power(HP) | 7 | 8 | 9 | 10 | 12 | 13 | 15 |
Displacement(m³/h) | 18.8 | 22.1 | 25.7 | 28.8 | 38.2 | 36.4 | 43.4 |
Starting Current(LRA) | 101 | 86-95 | 100-111 | 110-118 | 110-118 | 140 | 174 |
Rated Load Current(RLA) | 12.1 | 16.4 | 17.3 | 19.2 | 22.1 | 22.1 | 27.1 |
Max. Operating Current(MCC) | 17 | 23 | 24.2 | 26.9 | 31 | 31 | 39 |
Crankcase Heater Power(W) | 70 | 90 | 90 | 90 | 90 | ||
Size of Connecting Pipe(INCH) | |||||||
Outer Diameter of Wxhaust Pipe | 3/4 | 7/8 | 7/8 | 7/8 | 7/8 | 7/8 | 7/8 |
Outer Diameter of Suction Pipe | 7/8 | 1 3/8 | 1 5/8 | 1 5/8 | 1 5/8 | 1 5/8 | 1 5/8 |
Dimensions(MM) | |||||||
Length | 242 | 263.6 | 263.6 | 263.6 | 263.6 | 242 | 264 |
Width | 242 | 284.2 | 284.2 | 284.2 | 284.2 | 285 | 285 |
Height | 457 | 477 | 546.1 | 546.1 | 546.1 | 522 | 553 |
Foot Bottom Installation Dimensions(Aperture) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) | 190X190(8.5) |
Fuel Injection(L) | 1.8 | 2.51 | 2.25 | 3.25 | 3.25 | 3.3 | 3.3 |
Weight(KG) | |||||||
Net.W | 40 | 59.87 | 60.33 | 65.32 | 65.32 | 65 | 65 |
Gross.W | 44 |
Hits: 【Print】