Location:Index--->Product Center >> Danfoss Pressure Switches >> 060B017566 Danfoss Differential pressure switch, MP55A
|
|||||||||||||||||||||||||||
Product Description
060B017566 Danfoss Differential pressure switch, MP55A
MP Series oil differential pressure control
MP-MP-A pressure difference controller,
MP 54 and MP 55 oil differential pressure controller is a type of safety switch to prevent the refrigeration compressor oil pressure is too low.
If the oil pressure drops below the set value, at a certain time interval, the pressure difference controller operation, the compression.
MP 54 and MP 55 oil differential pressure controls are used as sefety switches to protect refrigeration compressors.
- MP 54 differential pressure control, fixed differential, low differential pressure
- Control voltage: 230 V or 115 V a. C. Or d. C.
- Permissible voltage variation: +10 - -15%.
- Max. Working pressure = 17 bar.
- Max. Test pressure = 22 bar.
- Operation range, LP side: -1 - 12 bar PE.
- Temperature compensation: The time relay is temperature-compensated in the range -40 - +60° C.
- Screwed cable entry: Pg 13.5.
- Max. Bellows temperature: 100° C.
- Enclosure: IP 20 to IEC 529.
More Models as below:
| Oil Pressure Controls | |
| 060B0172 | MP55, DIFF. P/CONTROL 90S DELAY |
| 060B0168 | PRESSURE CONT. OIL 90SEC |
| 060B0171 | PRESSURE CONT 60SEC DELAY |
| Type | Pressure | Max pressure | Agjust | Relay | Code No. | |||
| (bar) | p | (bar) | (s) | Connection | ||||
| (bar) | ¼in./6mm | 1m Cappliary ¼in.ODF ODF |
Cut 6mm |
|||||
| SAE | ||||||||
| MP54 | 0.65 | 0.2 | -1 ~ +12 | 0 | B | 060B0297 | ||
| 45 | A | 060B0166 | ||||||
| 0.9 | 60 | 060B0167 | ||||||
| 0.65 | 90 | 060B0168 | ||||||
| 120 | 060B0169 | |||||||
| MP55 | 0.3 ~ 4.5 | 45 | 060B0170 | 060B0133 | ||||
| 60 | 060B0171 | 060B0134 | 060B0188 | |||||
| 60 | 060B0178 | |||||||
| 90 | 060B0172 | |||||||
| 120 | 060B0173 | 060B0136 | ||||||
| 0 | B | 060B0299 | 060B0295 | |||||
| Code | Type |
| MP | |
| 060B029766 | differential pressure control MP 54 |
| 060B016666 | |
| 060B016766 | |
| 060B016866 | |
| 060B016966 | |
| 060B013366 | differential pressure control MP 55 |
| 060B013466 | |
| 060B013666 | |
| 060B017066 | |
| 060B017166 | |
| 060B017266 | |
| 060B017366 | |
| 060B017866 | |
| 060B018866 | |
| 060B029466 | |
| 060B029566 | |
| 060B029966 | |
| 060B017466 | differential pressure control MP 55A |
| 060B017566 | |
| 060B017666 | |
| 060B017766 | |
| 060B017966 | |
| 060B018266 | |
| 060B018366 | |
| 060B018466 | |
| 060B018566 | |
| 060B029666 | |
| 060B029866 |
Product details
| Gross weight | 0.9 Kilogram |
| Net weight | 0.802 Kilogram |
| Volume | 1.931 Liter |
| EAN | 5702428365567 |
| Adjustment | Cut out for falling pressure |
| Amb. Temp. Note | Bellows max 100 °C/212 °F |
| Ambient temperature range [°C] [max] | 60 °C |
| Ambient temperature range [°C] [min] | -40 °C |
| Ambient temperature range [°F] [max] | 140 °F |
| Ambient temperature range [°F] [min] | -40 °F |
| Approval | CCC CE CMIM EAC LLC CDC EURO-TYSK LVD RoHS RoHS China TYSK UKCA |
| China RoHS compliance | Yes |
| Contact differential [bar] | 0.2 bar |
| Contact function | SPDT |
| Contact rating | AC15=2 A, 250 V DC13=0.2 A, 250 V |
| Diff.press.setting range [bar] [max] | 4.5 bar |
| Diff.press.setting range [bar] [min] | 0.3 bar |
| Diff.press.setting range [MPa] [max] | 0.45 MPa |
| Diff.press.setting range [MPa] [min] | 0.03 MPa |
| Diff.press.setting range [psi] [max] | 65 psi |
| Diff.press.setting range [psi] [min] | 4.3 psi |
| Electrical conn. Male/Female | Female |
| Electrical connection | Screwed cable entry |
| Electrical connection size | Pg 13.5 |
| Electrical connection standard | DIN 40430 |
| EN 60947 electrical properties | Insulation: 250V Pollution degree: 3 Rated impulse voltage: 4 kV Short circuit prot, fuse: 2A |
| EN 60947 wiring properties | Flex, ferrules: 0.2-1.0 mm2 Flex, no ferrules: 0.2-1.5 mm2 Solid/stranded: 0.2-1.5 mm2 |
| Enclosure rating IP | IP20 |
| Equipment | Thermal time relay |
| EU RoHS compliance | Out of scope |
| Factory setting [bar] | 0.65 bar |
| Factory setting [psig] | 9 psig |
| In scope of WEEE and contain batteries | No |
| Max. test pressure [bar] Pe | 22 bar |
| Max. test pressure [psig] | 319 psig |
| Max. Working Pressure [bar] | 17 bar |
| Max. Working Pressure [psig] | 245 psig |
| Operat. range LP side [bar] Pe [max] | 12 bar |
| Operat. range LP side [bar] Pe [min] | -1 bar |
| Operat. range LP side [psig]Pe [max] | 175 psig |
| Operat. range LP side [psig]Pe [min] | -15 psig |
| Packing format | Multi pack |
| Pressure connection size | 3/8 |
| Pressure connection standard | ISO 228-1 |
| Pressure connection type | G |
| Pressure Male/Female | Male |
| Product accessories | Generic accessories |
| Product description | Diff. Pressure Switch |
| Product group | Switches and thermostats |
| Product Name Description | Differential pressure switch |
| Quantity per packing format | 21 pc |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
| Refrigerants | R11 R12 R123 R124 R134a R22 R404A R407A R407C R407F R407H R422B R422D R438A R448A R449A R449B R450A R452A R507C R513A R515B R717 |
| Relay release time [s] | 60 s |
| Reset function | Manual Min |
| SCIP dossier no. | d6c79256-254f-4a74-9674-fbd37043a658 |
| Serviceable | No |
| Type | MP55A |
| UK RoHS compliance | Out of scope |
| UL approved refrigerants | R11 R12 R123 R124 R134a R22 R404A R407A R407C R407F R407H R422B R422D R438A R448A R449A R449B R450A R452A R507C R513A R515B |