Product Description
Danfoss energy regulators KVC12 034L0143 4 mm Weld 1/2"
Product Description
Danfoss capacity regulators are used to adapt compressor capacity to actual evaporator load by supplying a replacement capacity in the form of hot/cool gas.
They are installed in a bypass line between the high and low-pressure sides of the refrigeration system and are designed for direct gas injection into the suction line. 693723 imposes a lower limit on the compressor suction pressue by supplying the low pressure side with replacement capacity in the form of hot gas/cool gas from the high pressure side.
Product Features
A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load.
They are placed in a by-pass between high and low pressure sides Of the refrigeration plant.
Regulating range 0.2 - 6.0 bar, factory setting 2 bar, max. working pressure 28 bar.
KVC type energy regulator is for regulating capacity of the compressor, to adapt to the evaporator load.
KVC type energy regulator is mounted on the refrigeration system of high / low pressure side of the road between the bypass pipe.
KVC helps to send the heat from high pressure side into the lower pressure side through the bypass line, to replace part of the load, so that the compressor suction pressure is not less than the minimum limit.
Brand: | Danfoss |
Colour: | - |
Connection Size: | - |
Connection Type: | - |
Length (M): | - |
Material Type: | - |
Model Number: | KVC 12 |
Nominal Running Current (A): | - |
Operating Temperature: | - |
Pressure: | - |
Voltage: | - |
Warranty: | 1 Year |
Phase: | - |
Refrigerant Suitability: | R134a, R404A, R507, R22, R407C |
Valve Connections: | - |
Defrost: | - |
Evaporator Fans: | - |
Cable Length (mtr): | - |
Type | Rated capacity | Solder connection ( inch) |
Code no. | |||
R22 | R134a | R404A/R507 | R407C | |||
KVC12 | 7.6 | 4.8 | 6.9 | 8.4 | 1/2 | 034L0143 |
KVC15 | 14.9 | 9.4 | 13.6 | 16.4 | 5/8 | 034L0147 |
KVC22 | 19.1 | 12 | 17.4 | 21 | 5/7 | 034L0144 |
DaNfOss MODEL KVC | |||||||
Part Number | Model Number | Regulating Range kPa (psig) |
Connections | Rated Capacity (kW) | |||
R22 | R134a | R404A | R407C | ||||
Capacity Regulator (hot gas Bypass) | |||||||
034L0141 | KVC12 | 20 to 600 (3 to 87) | 1/2" Fl.1 | 7.6 | 4.8 | 6.9 | 8.4 |
034L0042 | KVC15 | 5/8" Fl 1 | 14.9 | 9.4 | 13.6 | 16.4 | |
034L0043 | KVC12 | 1/2" ODS | 7.6 | 4.8 | 6.9 | 8.4 | |
034L0147 | KVC15 | 5/8" ODS | 14.9 | 9.4 | 13.6 | 16.4 | |
034L0144 | KVC22 | 7/8" ODS | 19.1 | 12 | 17.4 | 21 |